Showing results: 1591 - 1605 of 2477 items found.
-
LS2012 -
Lisun Electronics Inc.
• Measure Vrms, lrms, W, PF/Hz; • Measure AC, DC, AC+DC; • Automatic selecting, out of limit alarming, advance the work efficiency; • Voltage range: AC: 5-600V, DC: 1-600V. Current range: AC&DC: 0.005-20A with high measure accuracy. Auto range; • Accuracy: ± (0.4%reading + 0.1%range + 1digit).
-
IMV Corporation
The principle of Reciprocal Pendulum type Pickup is to induce voltage by reciprocal motion of the seismic mass with a coil in the magnetic field being suspended by a diaphragm or coil spring.. Because of its High Sensitivity and Advanced Linearity, it is suitable for detection of malfunction or deterioration of rotational machineries. Due to its structure, mounting should be done carefully for its direction or angle.
-
MIB -
GE Digital Energy
The MIB, a member of the M II family of economical and highly functional digital protection relays, is a microprocessor based relay that provides three phase high impedance differential protection for Substation Bus-bars of any voltage level. Use the MIB also to protect electrical machines like transformers, generators or motors against restricted earth faults.
-
ASM-E -
IPEC Ltd.
The ASM-E is a permanent partial discharge monitor for cables, switchgear and other high voltage assets.The ASM-E can be configured with up to 128 PD sensor channels. If excessive discharge is detected, the ASM-E raises an alarm that can be configured either locally or by email/SMS. This enables the long-term assessment of plant conditions to be carried out quickly and easily, from any remote computer.
-
Directional Impulse Detector -
Timco Instruments, LLC
The Directional Impulse Detector ( D.I.D.) is a compact handheld detector used to locate primary cable faults by sensing the magnetic field generated by the current pulse from a high voltage discharge device (thumper). A meter deflection indicates the intensity of the received signal. No deflection indicates that you have walked beyond the fault or away from the cable.
-
MC-1000 -
Martel Calibrators
The MC-1000 Process Calibrator provides high accuracy calibration, common DMM functions including read and source thermocouples, RTDs, Ohms, current, pressure, frequency and test continuity. This single calibration instrument will calibrate virtually any process device including: read and source thermocouples, RTDs, Ohms, Voltage, Current, Frequency, Pressure, and test continuity.
-
19200 -
Chroma ATE Inc.
Support Electrical Safety Test Scanning Support High / Low voltage circuit insulation (Switch module)Support 8 slots for plug-in (removable)Max. 9 slaves for multiple scanners (master/slave interface)Standard RS-232 and USB interface Optional GPIB interface CE Mark19200 can be installed in Chroma Electrical Equipment ATS model 8900
-
TPS3000 -
TDK-Lambda Corp.
The TPS3000 industrial AC-DC power supplies offer output power up to 3.2kW in a 2U high package with 3 phase supply input.Features include voltage and current programming, remote on/off, remote sense, a standby supply, PMBus communication, built in ORing FET and wide operating temparature range of -40°C to +70°C
-
Alpha-Omega Power Technologies, LLC.
Alpha-Omega Power Technologies (AOPT) specializes in high voltage pulsed power design and manufacturing. AOPT has industrial proven design ranging in power from a few hundred watts up to 50 kilowatts. We can design and build a complete turn-key system to meet your requirements. Please Contact Us to discuss your requirements.
-
SITEX SCU286 -
Teledyne ICM
The SCU286 has a system for direct measurement of the high voltage delivered by the X-Ray generator to guarantee the accuracy of the radiological parameters. Based on this data the control system maintains the stability of mA and kilovolts to within ± 0.5% in any selection range.SITEX & XS units offer a totally constant quality of exposures, as they are virtually exempt from fluctuations in the power supply.
-
IR-L 300 / IR-L 550 / IR-L 900 / IR-L 1000 -
Kusam Electrical Industries Limited
Infra Red Thermometer can be used in places where it is difficult for a normal temperature probe to reach or places where it is dangerous such as Heat Treatment Furnance, High Voltage Operating Plants, Molten Metal Temperature Monitoring, Kiln Temperature, Bearing Temperature, Energy Conservation, Scientific Experiment, Research & Development, Air conditioning, Petrochemicals, Automobile repair & Maintenance.
-
BAUR PHG 80 portable -
BAUR Prüf- und Messtechnik GmbH
Portable, high performance test generator with VLF truesinus technology. The BAUR PHG 70/80 portable VLF test systems are used for cable and cable sheath testing of medium-voltage cables of up to 50 kV and electrical equipment.* 3 voltage shapes in one device: VLF truesinus, VLF square wave and DC voltage* For medium-voltage cables of up to 50 kV operating voltage* Cable testing, fault conditioning, cable sheath testing
-
BAUR PHG 70 portable -
BAUR Prüf- und Messtechnik GmbH
Portable, high performance test generator with VLF truesinus technology. The BAUR PHG 70/80 portable VLF test systems are used for cable and cable sheath testing of medium-voltage cables of up to 50 kV and electrical equipment.* 3 voltage shapes in one device: VLF truesinus, VLF square wave and DC voltage* For medium-voltage cables of up to 50 kV operating voltage* Cable testing, fault conditioning, cable sheath testing
-
4167 MF -
Standard Electric Works Co., Ltd
● High Quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Test test leads are supplied as standard accessories for simplified two-wire measuring system.● Two insulation test voltages(DC) : 250V and 500V.● Alternation voltage measurement.● Battery life indicator.● Fuse protected.
-
YD-Series -
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
YD series HIPOT tester is applied to test the insulation ability of electric power equipments and insulation materials at power frequency high voltage. The insulation test result of the tester is go or not go. Also the YD series HIPOT tester is a universal power source in HV test. The maximum output voltage and capacity could be customized according the requirements of custom.The tester is consists of single HV transformer and main control box. There are two kinds of HV transformer according to the insulation materials of the HV transformer.They are dry HV transformer and oil HV transformer. For the dry HV transformer the insulation material is epoxy resin.For oil HV transformer the insulation material is insulation oil. The dry HV transformer has a smaller size and less weight than oil HV transformer. But the maximum output voltage is less than 100kv for dry HV transformer. The functions of the main control box are voltage output regulation, protection in emergency and voltage/current value indication